21–23 May 2018
Topland | Hotel & Convention Center Phitsanulok
Asia/Bangkok timezone

Session

A08: Instrument (Poster)

21 May 2018, 17:45
Topland | Hotel & Convention Center Phitsanulok

Topland | Hotel & Convention Center Phitsanulok

http://www.toplandhotel.com/index.php Phitsanulok, Thailand

Presentation materials

There are no materials yet.

  1. Mr Korkuson Masaen (Master's Degree Program in Physics, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    Over the last few years, study of microfluidic flow cytometry using electrical signals has developed at a fast pace. There are several electrical detection configurations but differential impedance sensing offers a greater advantage due to its capability of cancelling common noise from the detected signal, resulting in improved signal to noise ratio. This paper presents the simulation of a...

    Go to contribution page
  2. Dr Rakdiaw Muangma
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    The aim of this work was to design and invent Brinell hardness testing machine for in-house testing and used for evaluation of hardness properties of soft materials. In this representation, the coated-wood-free (CWF) paper with grammage at 300 grams were used as the sample, whereas, the indenter diameter and the dwell time of imprinting were used at 7.86 mm and 10 seconds, respectively. After...

    Go to contribution page
  3. Mr Siripong Watthanasongsin
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    In this research, cantilever based torque magnetometer was designed and built for investigation of magnetic properties of materials. Torque on magnetic moment of the sample was detected by the torsion and flexion of the cantilever. The laser beam deflected from the sample platform was detected by a quadrant photodiode. The system can be used to measure anisotropy direction of a permanent...

    Go to contribution page
  4. Ms Jidapa Jermjaroong, Ms Chanisara Pawirunsiri
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    Hemolytic disease of the newborn or erythroblastosis fetalis occurs when there is an incompatibility between the blood types of the mother and baby. In this condition, red blood cells of the newborn are broken down and destroyed (hemolysis). When the red blood cells break down, a substance called bilirubin is formed. The Bilirubin has a pigment or coloring, it causes a yellowing of the baby's...

    Go to contribution page
  5. Ridhvee Taleh
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    In this work, the 5 kW DC plasma torch system has been developed which is composed of the DC power supply unit and plasma torch head. The power supply unit provides the DC current up to 50 A, 5 kW. The plasma torch head is concentric type, whose cathode electrode is in the center of hollow cylindrical anode electrode. The anode is 10 cm long and its inner diameter is 5 mm. The gap between both...

    Go to contribution page
  6. Sakchai Chomkokard, Dr Noparit Jinuntuya (Department of Physics, Faculty of Science, Kasetsart University, Bangkok 10900, Thailand)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    We developed the temperature measurement for use in the process of calibrate gauge block. The measurement equipment sense the temperature by four Pt100 temperature sensor. This sensors are very small in size and can contact with not affect the gauge block temperature. The small size sensors ability to measure the temperature of tiny piece or a big size gauge block. This temperature equipment...

    Go to contribution page
  7. Pisitpong Hernmek
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    The low-cost hot plate temperature controller was developed using Arduino Uno R3 microcontroller board. The controller composed of the Arduino microcontroller which was the controller main part, a temperature sensor part and a 7-displays part for monitoring temperature values. The K- type thermocouple connected to MAX31850 IC was established for a temperature sensor. The 4-digit 7 segment...

    Go to contribution page
  8. Tommakran Pangya (091-8327296)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    The PID controller and real-time monitoring system for a low-temperature furnace was developed. The system has two part, the PID controller, and the real-time monitoring part. An Arduino mega2560 microcontroller board was used for measuring and control the furnace temperature. A type-K thermocouple and a MAX31850 IC was applied for a furnace temperature measurement. The microcontroller board...

    Go to contribution page
  9. Mr Kajornpop Toboonchuay (Mahidol University)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    To preserve good quality of a musical instrument, a study of its acoustic property is very crucial.. In this study, the directivity of a Thai Low-pitched Bowed String-instrument, so-called Saw-U, made by a renowned Thai musical instrument manufacturer is studied. The directivity is also quite important for other acoustical utilization, such as architectural acoustics and auralisation (e.g....

    Go to contribution page
  10. Ms Jongrak Borsup (Suranaree University of Technology, School of Physics)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    It is well-known that high quality gem stones are naturally rare. Thus, lots of effort have been spent to improve low quality gem materials to enhance their appearances. This work focuses on the characterizations of low quality Mogok ruby to provide the information for improving its color. UV-Vis spectroscopic, X-ray fluorescence spectroscopic and X-ray absorption spectroscopic techniques were...

    Go to contribution page
  11. Ms Sutharat Rattana
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    Pomelo is a tropical fruit that is widely cultivated in Thailand. The price is largely varied according to cultivars. Certain qualities can be observed from fruit exocarp but for fruit sweetness or sourness it is impossible to externally determine. In this work, we explore the relation between the electrical capacitance and the fruit pericarp using a parallel-plate system for four frequencies,...

    Go to contribution page
  12. Ms Miskawan Sripakdee (Suranaree University of Technology)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    This work demonstrates the capability of the BL7.2W:MX diffraction beamline at SLRI for investigation of crystallinity of nano-films. The beamline utilizes hard X-rays from a 6.5-Tesla Superconducting Wavelength Shifter, originally designed for protein crystallography. Its x-ray optical beamline employs a collimating mirror, double-crystal monochromator and focusing mirror. The photon energy...

    Go to contribution page
  13. Patapong Panpiboon
    21/05/2018, 17:45
    Astronomy, Astrophysics, and Cosmology
    Poster

    A new photometric data study of eclipsing binary system are presented. The accepted solutions of analyzing the light curve revealed that V608 Cassiopeiae is a contact binary with two solar-type spectra component. The primary component of this system is the massive one. The geometric configuration indicates that each component of V608 Cas exactly fills its limited Roche lobe and mass overflows...

    Go to contribution page
  14. ภนิตา ทองจำปา
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    Sound pollution has long been known to inflict problems to both humans and animals. Judging sound to be pollution does depend on situation. Typical protections come in many forms according to specific problem. Sound absorber is one of those forms playing an important role in reducing reverberating effect in rooms or auditoriums. General commercial absorbers are constructed from mineral wool or...

    Go to contribution page
  15. Mr Thammarong Thammarong Eadkhong
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    One of the key factors governing the sound absorption property of material is porosity. It provides localisation of acoustic energy and also dissipates the energy. To predict the acoustic absorbing potential of material, it is essential to determine its porosity. In this work, we present the use of air displacement volume and the concept of energy conservation to determine material porosity....

    Go to contribution page
  16. Meechai Homchan
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    In this project, quadcopter flight controller using microcontroller Arduino UNO R3 was built. The microcontroller Arduino UNO R3 is used because it can receive both digital and analog signals, there are several receive and output ports which can send PWM signal which is very useful for control brushless motors using PID algorithm that can govern such high rotational speed. The proposed...

    Go to contribution page
  17. Wanchaloem Poonsawat (Suranaree University of Technology (TH))
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    For the long shutdown of the LHC in 2019, Monolithic Active Pixel Sensors (MAPS) are being studied to use for the Inner Tracking System of ALICE detector. The pixel chips, manufactured by the TowerJazz with 180 nm CMOS imaging sensor process, have been characterized to produce the new sensor with lower material budget and higher granularity. The optimization of the pixel is determined from...

    Go to contribution page
  18. Dr Mudtorlep Nisoa (Division of Physics School of Science)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    In the small-scale palm mill industries, the processes have produced low quality crude palm oil. The oils have high free fatty acid content (FFA > 5) and low Deterioration of Bleachability Index (DOBI < 2), which are classified as grade B oils. Since, they used hot air for too long time in pre-treatment process. In this research, microwave will be used as heating source for pretreatment, to...

    Go to contribution page
  19. Dr Dussadee Rattanaphra (Thailand Institute of Nuclear Technology)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    The possibility of the determination of U and Th concentration in the Thai monazite ore processing samples using gamma-ray spectrometry technique was investigated. The studied samples were monazite ore, tri-sodium phosphate, mixed rare earth hydroxide, enriched cerium, uranium cake, thorium cake, La2O3 and CeO2. The measured activity concentrations of 238U and 232Th were converted into the...

    Go to contribution page
  20. Dr Gedsirin Eksinitkun
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    The identification of gunshot residue (GSR) dispersed in a shooting is important for forensic evidence to solve the firearm shooting crimes. In this experimental study, the residue of specific elements, namely: Lead (Pb), Antimony (Sb) and Barium (Ba) were compared using inductively coupled plasma mass spectroscopy from 4 types of 9 mm. ammunition labeled as A is Lead Round Nose (LRN) 135 gr.,...

    Go to contribution page
  21. bundasak angmanee
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    The controller and monitoring system of 1-10 kV high voltage power supply was developed. The system composed of an Arduino mega 2560 microcontroller boards, a digital to analog conversion (DAC) part, a high voltage module and the designed software on a personal computer. The software was developed by LabVIEW software for controlled the high voltage module and displayed the high voltage values....

    Go to contribution page
  22. Mr Sumit Jirungnimitsakul (Department of Physics and Materials Science, Chiang Mai University, Chiang Mai, 50000, Thailand)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    The objective of this study was to study the generated electrical signal of piezoelectric sensors patched on the various samples by using one single pulse. Piezoelectric sensors used in this study were the commercial piezoelectric buzzers which are PZT ceramic disk of 20 mm with brass plate of 27 mm in diameter. The generated electrical signals of piezoelectric sensors from aluminum plate,...

    Go to contribution page
  23. Ms Sawanee Jitphayomkun (Chulalongkorn University)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    In microelectronic industry, the lubricants are used in the wafer-to-chip grinding and lapping processes before device assembly step. The based-lubricant and additives play important roles in the product quality and reliability for those nano-scale fabrications. In this study, the tribological behaviors of AlTiC surface that sliding against AISI304 balls were studied in electronic-grade...

    Go to contribution page
  24. Ms Apirada Vijittumrongsuk (Department of Physics, Faculty of Science, Kasetsart University)
    21/05/2018, 17:45
    Instrumentation, Metrology and Standards
    Poster

    We examine the uncertainty of pH measurement by an Ion Sensitive Field-Effect Transistor, or ISFET. Due to its size and ability to simply integrated to measurement electronics, the sensor is suitable for pH measurement on the field. However, the uncontrolled environment can interfere the accuracy of the measurement. In this work we consider a mathematical model of pH measurement that involves...

    Go to contribution page