5–11 Jun 2022
McMaster University
America/Toronto timezone
Welcome to the 2022 CAP Congress Program website! / Bienvenue au siteweb du programme du Congrès de l'ACP 2022!

Session

DNP Poster Session & Student Poster Competition (4) | Session d'affiches DPN et concours d'affiches étudiantes (4)

T-POS-DNP
7 Jun 2022, 17:30
McMaster University

McMaster University

Presentation materials

There are no materials yet.

  1. Ms S. Kakkar (University of Manitoba, TRIUMF)
    07/06/2022, 17:30
    Nuclear Physics / Physique nucléaire (DNP-DPN)
    Poster Competition (Graduate Student) / Compétition affiches (Étudiant(e) 2e ou 3e cycle)

    Nuclear-physics experiments probe nuclear structure, nucleosynthesis and fundamental interactions, for which high precision and accurate mass measurements are critical inputs. TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) facility employs the Measurement Penning Trap (MPET) to measure masses of exotic nuclei to high precision and accuracy up to ~1e-10. To improve the resolving power...

    Go to contribution page
  2. Laura Gonzalez Escudero
    07/06/2022, 17:32
    Nuclear Physics / Physique nucléaire (DNP-DPN)
    Poster not-in-competition (Undergraduate Student) / Affiche non-compétitive (Étudiant(e) du 1er cycle)

    nEXO is a next generation detector to search for neutrinoless double-beta decay in Xe-136. This hypothetical decay violates lepton-number conservation, requiring the neutrino to be its own antiparticle and would imply the existence of physics beyond the Standard Model. As a potential upgrade to further improve nEXO’s sensitivity, the Ba-tagging technique is being developed to eliminate nearly...

    Go to contribution page
  3. Rachna Singh (McMaster University)
    07/06/2022, 17:34
    Nuclear Physics / Physique nucléaire (DNP-DPN)
    Poster Competition (Graduate Student) / Compétition affiches (Étudiant(e) 2e ou 3e cycle)

    The neutron dose responses of the tissue equivalent multi-element Thick Gas Electron Multiplier (THGEM) microdosimetric detectors have been computed by Monte Carlo simulations. The absence of wire electrodes in THGEM has immensely simplified the construction of multi-element detectors. Three muti-element configurations of 7x3, 19x5, 37x7 were used as the representative detector geometries and...

    Go to contribution page
  4. Mr Ruoyu Sun (McMaster University)
    07/06/2022, 17:36
    Nuclear Physics / Physique nucléaire (DNP-DPN)
    Poster Competition (Graduate Student) / Compétition affiches (Étudiant(e) 2e ou 3e cycle)

    We present optimization and characterization of a Si-plastic scintillator coincidence beta-ray spectrometer. Recent recommendation to lower the dose limit for the lens of the eye by International Commission on Radiological Protection posed new health physics requirement in the country. Beta-ray dosimetry is of great importance for nuclear industries, particularly during the maintenance...

    Go to contribution page
Building timetable...