Development of the Readout Electronics for the Large Area ¬3¬He Tube Array Detector in High Pressure Neutron Diffractometer at the China Spallation Neutron Source

1 Jul 2024, 18:14
1m
Main Auditorium (FMDUL)

Main Auditorium

FMDUL

Main Auditorium of the Faculty of Dental Medicine at the University of Lisbon (Faculdade de Medicina Dentária da Universidade de Lisboa)

Speaker

Weigang Yin

Description

The High Pressure Neutron Diffractometer (HPND) is designed to explore new phases and physical properties of materials under high pressure at the China Spallation Neutron Source (CSNS). A large-area 3He tube array detector has been adopted as position sensitive neutron detector. The 3He tube array contains 116 detection unit, each unit consist of eight 3He tubes. A dedicated readout electronics system is developed to acquire the neutron hit events, calculate the position and flight time information of the scattered neutrons. For each 8-3He-tube detection unit, the readout electronics consists of two 8-channel front-end boards (FEB) and one 16-channel digital acquisition (DAQ) board. The FEB converts the charge signal into a voltage pulse signal and pre-process the analog signals; The DAQ board performs analog-to-digital conversion, event processing and data communication. Test results shows that the readout electronics system could work well, and the position resolution of the detection unit is better than 8mm.