Conveners
Poster Session - NINST
- Fabiana Gramegna (INFN Laboratori Nazionali di Legnaro)
- Guido Martin (CEADEN, Cuba)
Nowadays, the experiments related to the High Energy Physics and others fields demand the use of detectors with greater radiation resistance, and the novel material GaAs:Cr had demonstrated excellent radiation hardness compared with other semiconductors. On the basis of the evidences obtained in the JINR experiment with the use of 22 MeV electrons beam generated by the LINAC-800 accelerator,...
In this work we calculated two kinetic parameters of the RECH-$1$ research nuclear reactor: the effective delayed neutrons fraction, $\beta_{eff}$, and the mean neutron generation time $\Lambda$ using the Monte Carlo codes MCNP6 [1] and Serpent 2 [2] and the neutron cross section library ENDFV.VII.$1$.
To calculate $\beta_{eff}$ we used the method proposed by Meulekamp and van der Marck[3]. In...
In this work the characterization of a multichannel analyzer conceived in the CEADEN and developed on the basis of an FPGA, is presented. The system consists of 2048 channels; 32 000 counts per channel at most; 4.5ns of sampling time and a dead time of 16ns. A differential non-linearity (DNL) of +3.62 ± 1.56 and a non-integral linearity (INL) of +0.29 ± 0.05, in addition with the increase of...
Nowadays, the use of Aqueous Homogeneous Reactors (AHR) for the production of medical isotopes, mainly 99Mo, is potentially advantageous because of their low cost, small critical mass, inherent passive safety, and simplified fuel handling, processing and purification characteristics. However, it faces some challenges to be successfully deployed for the production of medical isotopes. This...
The service provided by the Gamma Cameras (GC) in the nuclear medicine departments fails because of their breakdown, generally due to the associated electronics and not to the physical detection components. For this reason, it was decided to develop an electronic system that allows the recovery and optimization of disused GC, starting with the design of the preamplifier for each...
The advanced GaAs:Cr material for radiation detection is in the scope of many scientific and technological institutions in the world, as consequences of its proved superior properties and economic advantages. Experiments made at the JINR Dzhelepov Laboratory of Nuclear Problems for the energy calibration of a hybrid GaAs:Cr-based Timepix detector with alpha particles reaffirm that this device...
This paper describes the development of an instrument for Radiological Monitoring and Gamma Alarm (GAMAL01). It monitors the burst of radiation produced during a radioactive accident and triggers an alarm for evacuation in case the radiation exceeds an established threshold. The instrument consists of two sections, analog and digital.
Key words: Geiger Müller counters, data acquisition...
Positron emission tomography (PET) is one of the most important diagnostic tools in medicine, allowing three-dimensional imaging of functional processes in the body. It is based on a detection of two gamma rays with an energy of 511 keV originating from the point of annihilation of the positron emitted by a radio-labeled agent. By measuring the difference of the arrival times of both...
The chromium - compensated gallium arsenide is attaining a relevant position between the materials devoted to the development and fabrication of radiation detectors. This material shows high resistance to the radiation damage, high effective Z, relative low production cost, possibility to grow large area films, etc. Some results from the study of Timepix hybrid detectors based on GaAs:Cr by...
Giant-dipole- resonance photoneutrons (GRN) are produced by LINAC 2300 CX operating in the range of 15 MV. During radiotherapy treatment unwanted neutron dose is delivered to patients. To establish the thermal and epithermal photo-neutrons field during radiotherapy treatments Nuclear Track Methodology (NTM). The well tested polyallyldiclogola carbonate (PADC type CR-39 TM on that a thin boron...
High resistivity gallium arsenide compensated by chromium has demonstrated a good suitability as a sensor material for hybrid pixel detectors used in X-ray imaging systems with photon energies up to 60 keV. The material is available with thickness up to 1 mm and thanks to its Z number and fully active volume of the sensor high absorption efficiency in this energy region is provided. Although...
In recent years, CT has proven itself as a method of nondestructive research in biology, geology, industry, and other fields. However, until recently, the detectors used in CT recorded only the intensity of the radiation, losing information about the energy. The method of dual-energy CT partially corrects this deficiency. With the advent of hybrid matrix detectors with the single photon...
Among the most modern ionizing radiation detectors, the hybrid based on GaAs:Cr Timepix stands out as one of the most competitive due to its characteristics, such as its high Z and its strong resistance to radiational damage. In addition to their use in high energy physics research, they have been effectively employed in the medical visualization, spatial technologies, geological prospecting,...
The High Performance Light Water Reactor is one of the most promising concepts of the Fourth-Generation reactors. Uranium mono nitride (UN) and Uranium mono carbide (UC) as nuclear fuel alternative for the HPLWR, offer the advantage of high thermal conductivity as compared to UO$_2$. The use of coating can solve the problems of the reactive nature for UN and UC which arise when these fuels are...
The Generation IV Very High Temperature Reactor (VHTR) is envisioned as an outstanding prototype among the six nuclear systems propose in the Generation IV. The characteristics that highlights this reactor are focused in the low electricity generation costs, short construction periods, in proliferation resistance and physical protection. Nevertheless, it presents essential challenges to be...