Julio Nazco (HealthCare Center for Oncology Patients, Pinar del Rio, Cuba.), Freek Bakker (Radiotherapy Center of Suriname, Suriname.)Medical PhysicsPoster
The purpose of this work was to revise how well XiO treatment planning system (TPS 4.80 patch 03) Intensity Modulated Radiation Treatment (IMRT) calculations are delivered by an Elekta Synergy Platform-MLCi2 machine using Task Group 119 (TG119) benchmarked data of the American Association of Physicists in Medicine (AAPM) in order to implement future IMRT treatments at the Radiotherapy Center...
Go to contribution page -
Deijany Rodríguez Linares (Center for State Control of Drugs, Equipment and Medical Devices (CECMED), Havana, Cuba.)Medical PhysicsPoster
Background: Independent external audits play an important role in quality assurance in radiation oncology, for this reason the International Atomic Energy Agency (IAEA), in its technical document IAEA-TECDOC-1583, recommends a procedure to establish quality assurance of Radiotherapy Planning System (RTPS) using the IMRT Thorax Phantom (CIRS - 002LFC). The procedure is based on an anatomical...
Go to contribution page -
Lourdes M Garcia-Fernandez (R.S. McLaughlin Durham Regional Cancer Centre, Lakeridge Health, Canada.)Medical PhysicsPoster
Currently at our centre, the stereotactic program uses 6 MV cFF and forward planning techniques: cones for SRS, conformal MLC for SRT. Patients are immobilized with either the non-invasive Aktina stereotactic frame or a thermoplastic mask. Treatment localization is performed with CBCT. We are implementing DCAT and VMAT for SRT with 6 MV FFF to reduce treatment time, treat larger non-spherical...
Go to contribution page -
Yoval Aguiar Ferro (Centro de Atención al Paciente Oncológico. Pinar del Río, Cuba.), Julio Nazco Torres (Centro de Atención al Paciente Oncológico. Pinar del Río, Cuba.)Medical PhysicsPoster
This study provides dosimetric data from the commissioning of two Sensus SRT-100 50–100 kV X-ray units. Data collected during the commissioning process included: a) HVL, b) output (dose rate), c) applicator cone factors, and d) profiles. Percentages depth dose were not measured due to lack of resources. Farmer-type chambers (iba-FC65-G), and a thin-window parallel plate ion chamber...
Go to contribution page -
José Alejandro Fragoso Negrín (Instituto de Tecnologías y Ciencias Aplicadas, Universidad de La Habana (InSTEC-UH), La Habana, Cuba.)Medical PhysicsPoster
Several Monte Carlo (MC) codes are available for performing radiotherapy dose calculations, with acceptable accuracy. The objective of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on the absorbed dose evaluations. In order to evaluate the possible systematic differences, a comparison was made between different electromagnetic...
Go to contribution page -
Ángel A. Pérez (Nuclear Medicine Department, National Institute of Nephrology ‘’Dr. Abelardo Buch López’’, Cuba.)Medical PhysicsPoster
Relative renal function and differences in the images of kidneys through renal gammagraphy with radiopharmaceutical $^{99m}$Tc-MAG3 and $^{99m}$Tc-DMSA was compared. For the study a sample of 50 patients was analyzed, in which 75% were children. Images were acquired with a double-headed AnyScan SC gamma camera of MEDISO Company. The renal gammagraphy with $^{99m}$Tc-MAG3 was processed as a...
Go to contribution page -
Mr Diego Tellez (Universidad Distrital Francisco José de Caldas, Colombia.), Mr Steven Medina (Universidad Distrital Francisco José de Caldas, Colombia.), Dr Alfonso Leyva (Pontificia Universidad Javeriana, Colombia.), Dr Edwin Munévar (Universidad Distrital Francisco José de Caldas, Colombia.)Medical PhysicsPoster
Since its discovery in 1935 by J. Chadwick, neutrons have been used in many fields, from power production to medical applications. In particular, G. L. Locher in 1936 came out with the idea of using neutron capture for cancer treatments. Currently the Neutron Capture Therapy (NCT) stands for a binary treatment method that combines a cancer specific Boron ($^{10}$B) or Gadolinium ($^{157}$Gd)...
Go to contribution page -
Diego Tellez (Department of Physics, Universidad Distrital Francisco José de Caldas, Bogotá D.C., Colombia.), Steven Medina (Department of Physics, Universidad Distrital Francisco José de Caldas, Bogotá D.C., Colombia.), Edwin Munévar (Department of Physics, Universidad Distrital Francisco José de Caldas, Bogotá D.C., Colombia.), J. Alfonso Leyva (Department of Physics, Pontificia Universidad Javeriana, Bogotá D.C., Colombia.)Medical PhysicsPoster
After the discovery of neutrons, G. L. Locher proposed the idea of using neutron capture for cancer treatment - Neutron Capture Therapy (NCT). This treatment method combines either a Boron ($^{10}$B) or Gadolinium ($^{157}$Gd) labeled drug and an epithermal neutron beam suitable for neutron capture to take place within the treated tissues. With a branching ratio of approximately 94%, the...
Go to contribution page -
Y. Alexandra Pabon (Medical Physics Master Program, Pontificia Universidad Javeriana, Bogotá, Colombia.)Medical PhysicsPoster
In the last decades the use of the Human Amniotic Membrane (HAM) in regenerative and curative medicine has been significantly increased. The sterilization processes of the HAM are crucial for its clinical use. In order to preserve the main biophysical and biochemical properties of HAM, improvements are required in the sterilization procedures, in which some of the valuable HAM's properties are...
Go to contribution page -
Mr Osvaldo Brígido (Centro de Ingeniería Ambiental, Camagüey, Cuba.)Medical PhysicsPoster
It is recognised worldwide that the security of radioactive materials is very important and that the design of facilities where these sources are used and stored must cater for the implementation of good security measures, including the shielding of some treatment and diagnostic rooms. The radiation protection assessment of a nuclear medicine facility consists of the evaluation of the annual...
Go to contribution page -
H. Olaya Dávila (Physics Department, Universidad Nacional de Colombia, Bogotá D.C – Colombia)Medical PhysicsPoster
Was designed and produced a cylindrical phantom in PMMA material for evaluate the image quality parameters: spatial resolution, high and low contrast, magnification, uniformity and reproducibility of Hounsfield numbers for Computed Tomography (CT) through the formation of images in the acquisition of tomographic images. The phantom was designed and built under the recommendations of...
Go to contribution page -
Mrs Ivón Oramas Polo (Instituto de Pesquisas Energéticas e Nucleares, CNEN, SP, Brazil.)Medical PhysicsPoster
The $^{85}$Kr isotope is a beta-ray emitter (gas) with a half-life of 10.76 years. It is produced in the fission of Uranium and Plutonium. The sources of this isotope are the nuclear tests, the nuclear reactors and the reprocessing of nuclear fuel. In the gas release events around reactors, the $^{85}$Kr may represent a major hazard. In beta emitters, in order to evaluate the absorbed dose...
Go to contribution page -
Barbara E. García Moreno (Dpt. Desarrollo, Centro de Isótopos, Cuba.)Medical PhysicsPoster
14F7 is a murine monoclonal antibody that recognizes the ganglioside N-Glycolil GM3 and induces death in tumor cells that overexpress this ligand. Antibody fragments exhibit improved pharmacokinetic properties as compared to whole antibodies. The study was based on two assumptions: first, the h14F7-F(ab')$_2$ does not lose its biological activity; second, labelled with $^{99m}$Tc, have a more...
Go to contribution page -
José Antonio Diaz Merchán (Universidad Nacional de Colombia)Medical PhysicsPoster
In this work the study of the Deposited Dose Distributions in depth by Protons and Carbon Ions in different Phantoms, was made with Monte Carlo Method. Initially, a simulation of the interaction of the charged particles (Protons and Carbon Ions) with water was constructed with the Geant4 tool (Fig.1.). The Bragg peaks and Deposited Dose Maps at multiple energies within the therapeutic range...
Go to contribution page -
David Antonio Brito Imbaquingo (ICTP - UniTs)Medical PhysicsPoster
In lung cancer, SBRT is used to deliver high doses to a small dense GTV moving into a low-density tissue (margin generating the PTV). If IMRT or VMAT are used to treat such inhomogeneous PTV, a homogeneous dose distribution is achieved generating high photon fluence inside a 3D shell (PTV-GTV). Paradoxically the dose distribution is apparently uniform, but the GTV, which moves into the PTV,...
Go to contribution page -
Dayana Castillo Seoane (Oncology and Radiobiology Institute (INOR), 29th and E street, Vedado, P.O. BOX 10400, La Habana. Cuba.)Medical PhysicsPoster
The availability of tools for visualize, control, and track patient specific respiratory motion could improve the accuracy in radiation therapy for thorax and abdomen tumor lesion. If smaller treatment fields are used, there is the possibility of target may move out of the treatment field resulting in an under dose to the target and surrounding normal will be exposed.The goal of this work is...
Go to contribution page -
A. Martínez León (Instituto Superior de Tecnologías y Ciencias Aplicadas (InSTEC), Universidad de La Habana, Cuba.)Medical PhysicsPoster
There is sufficient information in vitro and in vivo that indicates that AT1 receptor (part of the blood pressure regulated system Renin-Angiotensin) is overexpressed in malignant tumor. The losartan is one of the most studied antagonist of this receptor, for that reason, this study evaluated the fluoro-alkyl losartan-derivatives ($^{18}$FAL) as potential candidates of $^{18}$F-labeled...
Go to contribution page -
Manuel Vega (Asesor RPR Hospital Cardiocentro Villa Clara. Cuba.)Medical PhysicsPoster
Very soon is going to work in Cardiological Center of Villa Clara, Cuba, a new brand of X ray Device, (that is X Ray in C Arm), that includes electrophysiology functions, in which the irradiation time might be longer in comparison with Hemodynamic Machines and interventionist cardiology, where take place several procedures of less duration such as angiographies and angioplasties. It is shown...
Go to contribution page -
Adlin López Díaz (Nuclear Medicine Department, Hospital “Hermanos Ameijeiras” Havana, Cuba)Medical PhysicsPoster
This research, propose a monitoring procedure of $^{131}$I intake of nuclear medicine workers using the thyroid probe of the Nuclear Medicine Department. The Thyroid Counter used is a gamma probe, equipped with a lead shielded NaI(Tl) scintillation detector of 30x30, also was studied the gamma camera Phillips Forte with NaI(Tl) 3/8" pinhole collimator-5mm. The efficiency calibration was...
Go to contribution page -
José Alejandro Fragoso Negrín (Instituto Superior de Tecnologías y Ciencias Aplicadas, Cuba.)Medical PhysicsPoster
Intra-Operative radiotherapy (IORT) is a very effective technique that has begun to be used in our region. It has proven to be a good alternative as part of the breast conserving surgery. Technical success is based on the administration of high doses to the lesion in a single treatment session of radiotherapy, during the same surgical operation, with multiple clinical advantages that are not...
Go to contribution page -
Adlin López Díaz (Nuclear Medicine Department, “Hermanos Ameijeiras” Hospital, Havana, Cuba.)Medical PhysicsPoster
The optimization of patient-specific treatment planning of hyperthyroidism with $^{131}$I is a desirable goal from medical and radiation protection point of view. The purpose of this work was to develop a software based on MATLAB, capable to handle non-uniform activity distribution at voxel level and made dosimetry calculation using the “S” factor from MIRD methodology, planning the...
Go to contribution page -
Eilen Llanes Veiga (Instituto Nacional de Oncología y Radiobiología (INOR), Cuba.)Medical PhysicsPoster
Total Body Irradiation (TBI) is a radiotherapy technique that consists of irradiating homogeneously the whole patients body and it is characterized by extended source to surface distances and the use of large irradiation fields. The limitations of the available input data and inherent problems with the calculation procedures make it very difficult to accurately determine the dose distributions...
Go to contribution page -
Francisco Pérez González (Hospital “V. I. Lenin”. Holguín. Cuba.)Medical PhysicsPoster
In radiotherapy and nuclear medicine processes, medical physic have a preponderant participation in the correct administration of prescript doses to a patient, so that if they differ more than a predetermined value to the prescription, become in radiological accident or a mistreatment.
Go to contribution page
In this paper is exposed a quantitative and qualitative analysis, based on Risk Matrix Method, particularly... -
L. García (Center for Technological Applications and Nuclear Development (CEADEN), Havana, Cuba.)Medical PhysicsPoster
Nanogels are extensively studied for diverse biomedical applications. One of the most relevant is the use as drugs nano-carriers for therapeutic purposes, increasing the bioactivity and transport of active components to specific sites or cells. Nanogels-based drug release formulations improve the effectiveness and safety of certain anticancer drugs and radiopharmaceuticals, minimizing its...
Go to contribution page -
Lourdes M Garcia-Fernandez (R. S. McLaughlin Durham Regional Cancer Centre, Lakeridge Health, Canada.)Medical PhysicsPoster
Purpose: The flattening filter free (FFF) mode (Elekta) was recently installed at our institution. We investigated FFF planning and delivery for stereotactic peripheral lung treatment as the increased dose rate of FFF mode can reduce the treatment time.
Go to contribution page
Methods: Ten lung cancer patients with peripheral lesions previously treated with VMAT SBRT were selected to span a range of target sizes and... -
David Adame Brooks (Radiation Medical Physics Group, Department of Biophysics, Medical Biophysics Center, Universidad de Oriente, Santiago de Cuba, Cuba.)Medical PhysicsPoster
Despite the clear evidence that computed tomography provides very valuable information for diagnosis, there is a potential risk for the use of ionizing radiation. In CT, decreasing the dose of radiation increases the amount of noise in the images; therefore, the noise can hide anatomical details and decrease the detection of injuries. The Bilateral filter, proposed by Tomasi and Manduchi, is...
Go to contribution page -
Gabriel de la Fuente Rosales (Instituto de Tecnologías y Ciencias Aplicadas, Universidad de La Habana (InsTEC-UH), La Habana, Cuba.)Medical PhysicsPoster
The Monte Carlo method (MC) has been commonly used in medical physics applications such as radiotherapy, radiation protection and nuclear medicine due to the stochastic nature of radiation and detection processes. In our country, during the last few years, new radiotherapy machines with novel technological advances have been acquired. Among this new equipment, the linear accelerator (linac)...
Go to contribution page -
Rogelio Manuel Diaz Moreno (Instituto Nacional de Oncología y Radiobiología, Cuba.)Medical PhysicsPoster
Sophisticated devices are used in Stereotactic Radiosurgery (SRS) for delivering small radiation beams in specific geometries. Computer planning systems are customized with specific dosimetric data corresponding to the specific machine.
Go to contribution page
At Instituto Nacional de Oncologia y Radiobiologia, an Apex micro multileafs collimator was adopted together with an Elekta Precise linear accelerator for SRS... -
Mr Raúl Argota Pérez (INOR, Cuba.)Medical PhysicsPoster
The IAEA is about to publish an IAEA/AAPM protocol for the dosimetry of small photon beams. The present paper inserts into an ongoing IAEA coordinated research project to test the applicability of the new code of practice.
Go to contribution page
Relative output factors were measured in water (SSD=90cm @10cm depth) for ten field sizes ranging from 0.49 to 11.3 cm of equivalent square. The collimation is made with the... -
Manuel A. Lores Guevara (Centro de Biofísica Médica, Universidad de Oriente, Santiago de Cuba. Cuba.)Medical PhysicsPoster
A NMR based experimental procedure to determine the dynamic viscosity ($\eta$) in Plasma solutionsis presented. An equation relating $\eta$ and the transversal proton magnetic relaxation time (T$_2$) is obtained after considering a fast exchange between the free and associated water inside the Plasma Solution, the dominant role of the associated water in proton magnetic relaxation, the...
Go to contribution page -
H. Olaya Dávila (Physics School, Universidad Pedagógica y Tecnológica de Colombia, Tunja- Colombia)Medical PhysicsPoster
A detailed simulation of cross radiation in the PET and CT detectors of the tomographic bimodal system for small animals ClearPET/XPAD3-CT, was made using the Geant4 Monte Carlo code. A positron emitter radioactive point source (FDG-$^{18}$F) was located in the center of the tomographic system, inside a spherical water phantom. Positron-electron annihilations occurring within the phantom...
Go to contribution page -
Mr Nahuel Facundo Martínez Clemente (Instituto de Física Arroyo Seco (UNCPBA) and CIFICEN (UNCPBA – CICPBA – CONICET))Medical PhysicsPoster
Real-time dosimetry for radiotherapy with high spatial resolution is a growing research field. Development of new radiotherapy techniques, such as intensity-modulated radiation therapy, stereotactic radiosurgery, and high dose rate brachyterapy among others, require high performance dosimetrics techniques. Even though different kinds of detection systems have been investigated to perform...
Go to contribution page -
Mr Rafael Alejandro Miller Clemente (Universidad de Oriente, Cuba.)Medical PhysicsPoster
The motivation of this analysis was the knowledge of quantitative association between CT dosimetric quantities and operational factors and devise scanner-specific optimization strategies. The measure of indexes of kerma free in air and in standard phantoms (in a Siemens Sensation CT scanner), provided the main data for identification of statistical associations with operational factors and...
Go to contribution page -
R. Figueroa (Centro de Física e Ingeniería en Medicina & Departamento de Ciencias Físicas & Universidad de La Frontera, Chile.)Medical PhysicsPoster
The traditional scheme for X-ray production is based on the well known X-ray tube, an evolution in technology started from the experiments performed by Crookes and finally by X-rays discovery by W. Röntgen in 1895. As known, X-ray tubes are mainly based on the impact of accelerated electron onto high atomic number anodes in order to produce photons by means of Bremsstrahlung and characteristic...
Go to contribution page -
Mr C.H. Souza (Instituto de Pesquisas Energéticas e Nucleares, Brazil.)Medical PhysicsPoster
In vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize a in vivo...
Go to contribution page