3–7 Jun 2018
Jackson Lake Lodge
America/Denver timezone

Session

Oral 7 - High Voltage Design

7O
5 Jun 2018, 15:30
Explorers Room

Explorers Room

Presentation materials

There are no materials yet.

  1. Dr William White (Sandia National Laboratories)
    05/06/2018, 15:30
    High Voltage Design, Devices, Testing, and Diagnostics
    Invited

    The Sandia National Laboratories Z machine is the world’s most powerful and efficient laboratory radiation source, capable of producing over 2 MJ and 300 TW of x-rays. For primary energy storage, Z uses thirty-six separate Marx banks, each comprised of sixty 2.6 µF capacitors rated for up to 100 kV. The total energy storage on Z is 25 MJ at maximum operating voltage (95 kV). Regular...

    Go to contribution page
  2. Mrs Sara Hahmady
    05/06/2018, 16:00
    High Voltage Design, Devices, Testing, and Diagnostics
    Oral Presentation

    PIN diodes are fabricated using high thermal budgets to form deep P+ anode and N+ cathode regions by either diffusion or ion-implantation. These doping methods come with significant difficulties the in fabrication process such as: doping fluctuation, doping activation and costly equipment. To overcome these issues related to fabrication and doping profile, a new approach called charge plasma...

    Go to contribution page
  3. Nicholas Kallas (Los Alamos National Labs)
    05/06/2018, 16:15
    High Voltage Design, Devices, Testing, and Diagnostics
    Oral Presentation

    Explosive Emission Cathodes (EEC), used for the generation of relativistic electron beams, require short rise-time high voltage pulses in order to reduce the extraction of off-energy electrons. To this end a risetime sharpening circuit has been developed at the Los Alamos National Laboratory. The circuit consists of a ~7.8nF water filled peaking capacitor with an integrated self-breakdown...

    Go to contribution page
  4. Mr Michael Osemann (Ampegon-PPT GmbH)
    05/06/2018, 16:30
    High Voltage Design, Devices, Testing, and Diagnostics
    Oral Presentation

    A classical insulation problem occurring in many pulsed power and high voltage
    applications is to feed high-voltage-carrying conductors through a conductive wall
    at low (or even ground) potential. An ongoing development for a kicker
    application utilizes a pulse forming line (PFL) with a charging voltage of up to
    80kV. Since both cable ends must be connected within two oil tanks,...

    Go to contribution page
  5. Mr Zhitong Jiang (Xi'an Jiaotong University)
    05/06/2018, 17:00
    High Voltage Design, Devices, Testing, and Diagnostics
    Oral Presentation

    Dry-type air-core reactor used as AC filter reactors is one of the main noise sources in HVDC converter stations. The research on the vibration characteristics of the dry-type air-core reactor is of great significance for the design of noise reduction measures. Based on the assumption of linear vibration system, IEC 60076-6:2007 suggests to use sum frequency, difference frequency and double...

    Go to contribution page
  6. Dr Yuhang Shi (State Key Lab of Electrical Insulation and Power Equipment, Xi’an Jiaotong University)
    05/06/2018, 17:15
    High Voltage Design, Devices, Testing, and Diagnostics
    Oral Presentation

    The transformer winding will flow a larger impact current in the event of an external short circuit, causing strong vibration, resulting in winding loose and deformation. The loss of short-circuit withstand capability of winding is not a one-time process, but accumulated over the years. As the mechanical condition of winding deteriorates, the safety and stability of transformers are affected....

    Go to contribution page
Building timetable...