A Complementary split Ring resonator is proposed for the purpose of permittivity detection of several industrial solvents. In this design an Interdigital Capacitor topology is used for enhancing the electrical field intensity and interaction with the material under test (MUT). Industrial Scientific and Medical (ISM) band frequency of the range 2.4 GHz to 2.5 GHz have been chosen as the operating frequency of this CSRR-IDC sensor. This frequency range is chosen because of the license free application and it provides easy integration with RF equipment used in industrial, medical and scientific field while avoiding interference. The sensor is designed and simulated in Ansys HFSS (High Frequency Structure Simulator) simulation software and designed on Rogers R040350 as a low loss substrate having relative permittivity of 3.66 and loss tangent 0.004. The sensor exhibits a transmission notch of more than 20 dB and a Q factor greater than 100 which indicates high sensing capability and overall resolution of the sensor. The simulated sensor has been successfully tested on several industrial solvents having permittivity values ranging from 1-80 and it could reliably and accurately determine permittivity of unknown solvents with a high sensitivity and minimal error.
Keywords: Complementary Split Ring Resonator, Interdigital Capacitor, Permittivity, HFSS