Speaker
Description
This work presents the first oxygen ion beam tests at MedAustron, which aimed at assessing the feasibility of using the existing 14.5 GHz Electron Cyclotron Resonance Ion Sources (ECRIS) (S2 and S3) installed at MedAustron to generate $^{16}\mathrm{O}^{6+}$ beams. In future studies, these beams shall then be further transported through the LINAC before being stripped to $^{16}\mathrm{O}^{8+}$ and injected into the synchrotron.
To enable $^{16}\mathrm{O}^{6+}$ beam generation from the ion sources, dedicated adjustments of ion source parameters and source branch magnet settings were performed, followed by systematic optimization and characterization of the beam properties in the ion source branch.
The results demonstrate the technical feasibility of using MedAustron's ECRIS infrastructure to produce $^{16}\mathrm{O}^{6+}$ beams with intensities that are preliminarily assessed to be usable for research and clinical application.
Oxygen ion beams could further be used for mixed-beam applications, e.g. mixing them with helium beams. As for mixed carbon-helium ion beams, $\mathrm{O}^{8+}$ would be used for tumor treatment, while $\mathrm{He}^{2+}$, featuring approximately four times the range of $\mathrm{O}^{8+}$ in matter, could be used for online range verification. At MedAustron, oxygen beams can be produced from the S2 ion source, which is also used for carbon beam generation. Therefore, the operational scheme for carbon/helium mixed beams (double multiturn injection coming from two different ion sources) could be applicable for oxygen/helium operation as well.