Experimental Study on Large Cooling Capacity GM-JT Cryocooler in Liquid Helium Temperature Range

28 Oct 2026, 13:45
1h
Waaier (University of Twente)

Waaier

University of Twente

Hallenweg 23 7522 NH Enschede Netherlands
Poster Novel Cryogenic and HTS Technologies Poster session

Speaker

Dr Yunhao Cui (Technical Institute of Physics and Chemistry of the Chinese Academy of Sciences (TIPC-CAS))

Description

The Joule-Thomson (JT) cryocooler precooled by Gifford-Mcmahon (GM) cryocooler features high cooling efficiency and large cooling capacity, with a compact configuration, no moving parts at the cold end, and the capability for long-distance cooling power transport, making it suitable for applications such as superconducting electric levitation, gas liquefaction, and pre-cooling of millikelvin-level cryocooler units. In this study, a large-capacity GM–JT cryocooler operating in the liquid helium temperature range is experimentally investigated. The configuration of the experimental system and the overall cryocooler architecture are described, followed by offline performance tests of the JT compressor to characterize its operating characteristics. The cooling performance of the integrated GM–JT cryocooler is evaluated under different operating conditions. The experimental results demonstrate that the cryocooler achieves a cooling capacity of 5.9 W at 4.2 K with a total input power of 9.0 kW, corresponding to a relative Carnot efficiency of 4.43%.

In this work, an experimental investigation of a large-capacity GM–JT cryocooler operating in the liquid helium temperature range is conducted. The study includes offline performance testing of the JT compressor and integrated low-temperature performance evaluation of the complete GM–JT cryocooler on a dedicated experimental platform. Cooling capacity, input power, and relative Carnot efficiency are systematically measured under steady-state operating conditions. The experimental results show that the cryocooler achieves a cooling capacity of 5.9 W at 4.2 K with a total input power of 9.0 kW, corresponding to a relative Carnot efficiency of 4.43%.

Submitters Country China
Are you a student? No
Author Affiliations & Email Addresses I confirm that valid email addresses and affiliations have been added for all co-authors.
Co-Author Affirmation By clicking here, I, the submitting author, affirm that all co-authors know of and concur with the submission of this abstract.

Author

Dr Yunhao Cui (Technical Institute of Physics and Chemistry of the Chinese Academy of Sciences (TIPC-CAS))

Co-authors

Prof. Ercang Luo (Technical Institute of Physics and Chemistry of the Chinese Academy of Sciences (TIPC-CAS)) Mr Junwei Chen (Technical Institute of Physics and Chemistry of the Chinese Academy of Sciences (TIPC-CAS)) Prof. WEI Dai (Technical Institute of Physics and Chemistry of the Chinese Academy of Sciences (TIPC-CAS)) Xiaotao Wang (Technical Institute of Physics and Chemistry of the Chinese Academy of Sciences (TIPC-CAS))

Presentation materials

There are no materials yet.