Application of CRDS for Monitoring Gaseous Fission Products in Research Reactors

Dec 9, 2026, 11:00 AM
1h 40m
IPEN

IPEN

Cidade Universitária - Bairro Butantã CEP: 05508-000 - São Paulo - SP
Poster Applications of Nuclear Techniques Poster

Speaker

Ms Priscila Matos Santos (IPEN-CNEN - University of Sao Paulo)

Description

The safe operation of nuclear research reactors, such as the IEA-R1 at the Nuclear and Energy Research Institute (IPEN), relies on continuous monitoring to prevent and detect fuel element (U_3Si_2-Al) failures. When cladding degrades, noble gases like Xenon (Xe) and Krypton (Kr) are rapidly released into the primary cooling water and migrate to the pool surface. Detecting these trace gases serves as a highly sensitive early warning indicator of incipient failure prior to gross contamination. Traditional radiometric monitoring techniques can be significantly complemented by advanced optical methods. Cavity Ring-Down Spectroscopy (CRDS) has emerged as an ultrasensitive, near real-time optical alternative. Unlike conventional absorption spectroscopy, CRDS measures the decay time of a light pulse confined within a high-finesse optical cavity. This temporal measurement renders the technique immune to laser intensity fluctuations, enabling detection limits at the parts-per-billion (ppb) scale.
This work aims to develop and implement a benchtop CRDS system targeting the 631.8 nm electronic transition of Xenon to assess structural integrity in research reactors. The experimental setup employs a nanosecond pulsed Optical Parametric Oscillator (OPO) pumped by a Nd:YAG laser. The excitation beam was characterized and coupled into a 50 cm linear optical cavity formed by two high-reflectivity plano-concave mirrors (R > 99.9 %), designed following strict optical stability criteria.
Preliminary results successfully demonstrated optical confinement within the cavity. Initial signal acquisition and alignment were validated using a 32-channel multispectral Licel SP32 spectrometer. Ring-down decay curves were registered under atmospheric air and vacuum (10^[-3] mbar) conditions. The evacuated cavity exhibited a substantially longer decay tail, corroborating the elimination of Rayleigh scattering and molecular absorption losses.
However, data analysis indicated that a mono-exponential fit inadequately describes the decay curve due to the simultaneous excitation of multiple transverse cavity modes. Furthermore, the 50 ns temporal resolution of the spectrometer proved insufficient to capture the rapid initial transient accurately.
To overcome these artifacts, the methodology is transitioning to a high-speed data acquisition scheme utilizing a single-channel Photomultiplier Tube (PMT) coupled to a 2.5 GS/s digital oscilloscope, elevating the temporal resolution to 0.4 ns. This upgrade will provide the continuous, high-density data required for precise bi-exponential mathematical fitting, allowing the isolation of the fundamental mode lifetime. Future steps focus on system calibration with controlled Xe traces to define the setup's limit of detection before sampling actual reactor off-gases.

Keywords Cavity Ring-Down Spectroscopy, Fission Gases, Fuel Failure, Xenon
Proceedings Publication Intent Yes
Student Award Eligibility yes
Financial Support Request yes

Author

Ms Priscila Matos Santos (IPEN-CNEN - University of Sao Paulo)

Co-authors

Mr Leonardo Trindade (IPEN-CNEN - University of Sao Paulo) Mr Marcus Raele (IPEN-CNEN - University of Sao Paulo)

Presentation materials