Dec 7 – 10, 2026
IPEN
America/Sao_Paulo timezone

Extending Time-Interval Distribution (TID) Analysis to Long-Lived Nuclides: A Comparative Study for In-116m and Au-198

Dec 9, 2026, 11:00 AM
1h 40m
IPEN

IPEN

Cidade Universitária - Bairro Butantã CEP: 05508-000 - São Paulo - SP
Poster Applications of Nuclear Techniques Poster

Speaker

Guilherme Zahn (Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP)

Description

The accurate determination of nuclear half-lives is fundamental for applied radiation metrology and spectroscopy. This study presents a comparative analysis of two distinct methodologies for measuring the half-lives of In-116m and Au-198: the traditional approach, which relies on the analysis of successive measurement intervals, and a temporal analysis approach utilizing Time-Interval Distribution (TID) coupled with Maximum Likelihood Estimation (MLE). Data acquisition was performed using a high-purity germanium (HPGe) detector coupled to a CAEN v1724 digitizer, enabling high-resolution list-mode temporal and energetic data recording.

While TID analysis via MLE is a well-established technique for characterizing very short-lived radionuclides, its application to longer-lived nuclides -- specifically those with half-lives on the order of several minutes to a few days -- has been far less explored. This work evaluates the viability, precision, and potential statistical advantages of extending the TID/MLE methodology to these longer temporal domains, avoiding the information loss and discretization associated with predefined counting intervals.

The likelihood formulation incorporates a dead-time model, allowing extension to high-count-rate measurements. Although dead-time effects were negligible under the experimental conditions investigated here, the formulation remains valid for future applications involving higher activities.

The radioactive sources of $^{116m}$In and $^{198}$Au were produced by irradiating a 1g sample of each element together in an AmBe neutron irradiator ($\phi_{th} = 10^5 cm^{-2} \cdot s^{-1}$) for 5 days. The samples were then counted separately in the same HPGe detector - the In sample was counted for 18~h ($\sim 18$ half-lives), then the Au sample was counted for 280~h ($\sim 4.3$ half-lives). The same list-mode acquisition data was used for both the TID and the regular binned analyses, and the results were compared.

The results contrast the performance and uncertainties of the TID/MLE method against the traditional successive measurement technique, discussing the suitability and possible shortcomings of list-mode data temporal analysis for longer-lived nuclides like $^{116m}$In and $^{198}$Au-198.

Keywords Nuclear Spectrometry, Half-Life Determination, TID
Proceedings Publication Intent Yes
Student Award Eligibility no
Financial Support Request no

Author

Guilherme Zahn (Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP)

Presentation materials

There are no materials yet.