W7-X is a steady state capable optimized stellarator. The main heating system is electron cyclotron resonance heating (ECRH) operating at 140GHz providing up to 9MW microwave power.
A set of diagnostics has been developed to protect the machine from non absorbed ECRH power which can easily damage in vessel components.
The power is launched into the machine by front steerable quasi-optical launchers in X- or O-mode. While in X-mode the first pass absorption is ~99%, it is only 40... 70% in O-mode. The non absorbed power hitting the inner wall is measured by waveguides embedded in the first wall (ECA diagnostic).
In order to prevent the inner wall from overheating or arcing, a near-infra red sensitive video diagnostic with a dynamic range of 450...1200°C was integrated in the ECRH launchers. Thermal calculations for the carbon tiles predict a temperature increase above the detection threshold for scenarios of plasma start-up failure or poor absorption on a time scale of ~100ms and the risk of overheating after ~300ms. However, no temperature rise above the detection threshold could be observed in experiments with failed break down, i.e. poor ECRH absorption for up to 100ms.
The stray radiation level inside the machine is measured by so called sniffer probes which were designed to collect all radiation approaching the probing surface independent of incident angle and polarization. Five sniffer probes are installed at different toroidal positions. They were absolutely calibrated.
The sniffer probes are integrated in the ECRH interlock system. During the first operational phase of W7-X this was the only available plasma interlock system. The signal quality proofed to be high enough for a reliable termination in case of poor absorption. After a breakdown phase of ~10ms, the sniffer probe signals dropped by more than an order of magnitude. However, especially in the very first days of operation, most discharges died by a radiative collapse due to impurity influx. In this case the heating power was reliably switched off due to the increased level of stray radiation.
During OP1.1 the gyrotrons which are mostly capable of delivering >900kW power were operated at reduced power to increase the reliability. At maximum power there is an increased risk of losing the main mode in the gyrotron and thus a stop of RF emission. This causes an interlock for the gyrotron. An intelligent control system being able to operate stabile at maximum output power is currently being developed. One approach is to bring the gyrotron back in operation after a mode loss by switching off the HV supply for a short time (<1ms) and then back on at a slightly lower value. The second approach is a feedback control system to stabilize the output power by identifying a pre cursor signal for a mode loss and minimizing it. The mode activity at parasitic frequencies has been identified a possible pre cursor for a feedback control system.