16–20 Dec 2026
IIT Hyderabad
Asia/Kolkata timezone

Numerical simulation of effective gain and ion backflow in quadruple GEM detectors across different hole pitch dimensions

Not scheduled
20m
CCE (IIT Hyderabad)

CCE

IIT Hyderabad

https://physics.iith.ac.in/daehep2026/
Oral

Speakers

Ajay Kumar (Banaras Hindu University)Mr Rajiv Gupta (Banaras Hindu University)

Description

Quadruple GEM detectors consisting of four GEM foils cascaded perpendicular to the direction of primary electrons help reduce ion backflow while maintaining sufficient gain. Simultaneously satisfying these two operational requirements is essential in high-rate environments such as the ALICE Time Projection Chamber. Additionally, the cascading design enables low-voltage, discharge-free, and low-gain fluctuation operation. An innovative approach involves arranging GEM foils in an SP-LP-LP-SP configuration, where SP and LP denote a standard hole pitch of 140 µm and a large hole pitch of 280 µm, respectively. This arrangement effectively reduces ion backflow, thereby preventing space-charge accumulation that would otherwise distort electric field lines and consequently degrade detector performance. While most experimental and simulation studies are based on these two hole pitches, a comprehensive simulation study for various pitch dimensions remains limited. In our earlier studies [1,2], we have comprehensively investigated single and triple GEM detectors consisting of hole pitches of 140 µm, 90 µm, and 60 µm. The detailed study evaluated effective gain, collection efficiency, electron transparency, and transverse diffusion of the electron cloud as functions of various geometrical, field, and operating parameters. In our recent work on a quadruple GEM detector [3], we focused on benchmarking the ANSYS and Garfield++ framework to effectively simulate the detector gain and ion backflow fraction (IBF). In this work, we extend the simulation framework to evaluate quadruple GEM detectors with hole pitches from 70 to 280 µm. During the geometrical modeling, the ratio of pitch to outer hole diameter to inner hole diameter is kept constant at 140:70:50, based on standard designs. The electric field distribution and transport behavior of avalanche electrons across each configuration are discussed to provide greater insights into pitch variation. As performance analyses for reduced hole pitch GEM foils in quadruple GEM configurations remain limited, this study will provide a broader understanding of the hole pitch on effective gain and IBF.
1. R. Gupta, G. Devi, S. Saxena, A. Singh, and A. Kumar, Simulation-based performance comparison of varied pitch sizes GEM detectors, Nucl. Instrum. Methods Phys. Res. A 1082, 171046 (2025), doi:10.1016/j.nima.2025.171046.
2. R. Gupta, S. Saxena, and A. Kumar, Effect of hole pitch reduction on electron transport and diffusion in Triple GEM detectors, Nucl. Instrum. Methods Phys. Res. A 1087, 171931 (2026), doi:10.1016/j.nima.2026.171931.
3. R. Gupta et al., “Preliminary Simulation and Validation of Quadruple GEM Detector using ANSYS and Garfield++,” Springer Proceedings in Physics (2026), https://link.springer.com/book/9789819262403.

Tracks Accelerator Physics, Instrumentation and Future Experiments

Authors

Ajay Kumar (Banaras Hindu University) Mr Rajiv Gupta (Banaras Hindu University)

Co-author

Ms Sunidhi Saxena (Banaras Hindu University)

Presentation materials

There are no materials yet.