India is a founder member of the international collaboration for the construction of the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. Bose Institute, Kolkata, serves as the nodal Indian institution for coordinating the Indian participation in the FAIR programme and is involved in the Compressed Baryonic Matter (CBM) experiment at FAIR. The CBM experiment requires detector systems capable of reliable operation in environments with high particle flux. Gas Electron Multiplier (GEM) detectors are among the gaseous detector technologies considered for such high-rate applications because of their high-rate capability.
In this work, the charging-up behaviour and performance stability of a GEM detector are investigated under prolonged X-ray irradiation. Continuous irradiation is used to study the evolution of the detector response with irradiation time, with particular focus on the changes in gain, energy resolution, and detector current variation. The time-dependent response of the detector is studied to characterise the initial charging-up process and its subsequent evolution under sustained irradiation. The measured X-ray spectra are analysed at different irradiation intervals to follow changes in the detector gain and energy resolution. The influence of the accumulated charge on the detector response is also examined to identify the stability of GEM operation at high irradiation rates. The experimental results provide an assessment of the charging-up behaviour and performance evolution of GEM detectors under prolonged irradiation, which is relevant to their application in high-rate particle detection systems.
| Tracks | Accelerator Physics, Instrumentation and Future Experiments |
|---|