Speaker
Description
The Silicon Tracking System (STS) is the core tracking detector of the fixed-target Compressed Baryonic Matter (CBM) experiment at the future FAIR facility. It employs double-sided silicon microstrip sensors read out by custom SMX ASICs and is designed to operate at very high interaction rates while maintaining a low material budget. The sensors are assembled into ladders comprising two to ten detector modules and integrated with powering and readout electronics into 20 Half-Unit structures.
The powering of the STS modules presents significant challenges due to the symmetric high-voltage biasing of the sensors and the grounding requirements of the front-end electronics. The low-voltage power distribution employs a two-stage regulation scheme, in which radiation-tolerant FEAST DC--DC converters, compatible with operation in the CBM magnetic field, are followed by custom low-dropout regulators (LDOs) providing stable $1.2$ and $1.8,\mathrm{V}$ supplies to the front-end ASICs.
This work presents the electrical and thermal characterisation of a partially integrated STS Half-Unit. Supply voltages and currents were measured at different points along the low-voltage distribution chain for multiple operating configurations of the front-end electronics. These measurements were used to evaluate the power consumption, voltage drops, and available voltage margins across the system. In parallel, infrared thermography was employed to investigate heat dissipation and the performance of the cooling system at critical components, including low-voltage cables, FEAST converters, and front-end boards.
The measurements demonstrate stable operation of the Half-Unit over the investigated operating conditions. The observed load-dependent voltage drops identify the most critical elements of the low-voltage distribution chain, while the thermal measurements indicate effective heat removal from the powered structure. These results provide an experimental validation of the STS Half-Unit powering and cooling concept and support its further development towards series integration of the detector.
| Tracks | Accelerator Physics, Instrumentation and Future Experiments |
|---|