The High-Luminosity LHC requires a complete redesign of the CMS Level-1 Calorimeter Trigger, which must reconstruct and calibrate calorimeter objects at 40 MHz under an average pileup of 200. The Phase-2 trigger system is built on 34 APx ATCA processing cards hosting Xilinx VU13P-2 FPGAs and is organised into a Regional Calorimeter Trigger (RCT) layer and a Global Calorimeter Trigger (GCT) layer comprising Barrel, Endcap and Sum cards, with outputs delivered to the Correlator and the Global Trigger.
We present the current status of the firmware, developed with Vitis HLS and Vivado. Each card combines a common APx firmware shell with algorithm IP cores mapped across the four SLRs of the device. In addition to the Vitis IP cores containing core algorithms, various switching, demultiplexing and time-multiplexing blocks developed in VHDL are also implemented. Calibration and working-point constants are held in AXI-Lite registers and can be reloaded and applied in real time without reprogramming the FPGA. Major design considerations involve the 360 MHz clock constraint, a fixed latency budget of 1.2us, and the resource and routing limits of the VU13P-2.
Validation is performed with the FEAST framework (FPGA Environment for Algorithm Slice Tests), which allows a full-scale virtual system test to be executed on a limited number of physical devices. A complete CaloL1 slice test comprising 34 virtual FPGAs and more than 3400 interconnections has been executed successfully on a single physical APx card.

Tracks Accelerator Physics, Instrumentation and Future Experiments

Author

Mr Abhinav Mohan (University of Hyderabad (IN))

Presentation materials

There are no materials yet.