Speaker
Description
The Indian Dark matter search Experiment (InDEx) is a direct dark matter detection experiment aimed at exploring the low mass WIMP parameter space using superheated droplet detectors containing $C_2H_2F_4$ as the active liquid. InDEx measurements have been carried out at different operating temperatures corresponding to different recoil energy thresholds, including $5.87 keV, 1.95 keV$ and $0.61 keV$ runs. In the present work, we investigate the detector response and dark matter sensitivity in the low energy region, with recoil energy thresholds extending from $1.95 keV$ down to $0.61 keV$. The difference of event rates measured at the two thresholds enables us to reduce the contributions from background components common to both measurements. The resulting rate is studied with the expected detector response to nuclear recoils, and the corresponding sensitivity to spin-independent (SI) WIMP interaction is evaluated. The most sensitive SI cross section obtained in the present analysis is $2.21 \times 10^{-38}\ \mathrm{cm}^2$, corresponding to a WIMP mass of $4.5 GeV/c^2$. The lower threshold enhances the sensitivity to low energy nuclear recoils and provides an opportunity to probe the lower WIMP-mass region. The present status of the InDEx and the ongoing analysis will also be discussed.
| Tracks | Astroparticle Physics & Cosmology |
|---|