16–20 Dec 2026
IIT Hyderabad
Asia/Kolkata timezone

Exploring the sensitivity of InDEx to CRDM with a surface run

Not scheduled
20m
CCE (IIT Hyderabad)

CCE

IIT Hyderabad

https://physics.iith.ac.in/daehep2026/
Oral

Speaker

Ms Mili Mandal (Saha Institute of Nuclear Physics, Homi Bhaba National Institute)

Description

Cosmic Ray Boosted Dark Matter (CRDM) provides a promising way to search for sub-GeV Dark Matter (DM), which is difficult to detect using conventional direct detection experiments. In the CRDM scenario, high energy cosmic rays, mainly protons and helium nuclei, scatter with DM particles in the Galactic halo and transfer energy. This produces a population of boosted dark matter particles with much higher kinetic energies than conventional halo dark matter. These boosted particles can produce detectable nuclear recoils even for DM masses much lower than the usual detection limit. The CRDM flux depends on the cosmic-ray spectra, scattering kinematics, DM - nucleon scattering cross-section, nuclear form factors, and the energy loss of boosted DM while passing through the Earth's atmosphere and crust. The Indian Dark Matter Search Experiment (InDEx) uses a Superheated Liquid Detector (SLD) containing C$_2$H$_2$F$_4$ (tetrafluoroethane) as the active target medium. When sufficient energy is deposited inside a superheated liquid droplet, a bubble is formed, producing an acoustic signal that is detected using acoustic sensors. The carbon and fluorine nuclei in C$_2$H$_2$F$_4$ can provide sensitivity to the low energy nuclear recoils expected from CRDM interactions even at moderate thresholds. A dedicated surface measurement was carried out at the Saha Institute of Nuclear Physics using a 500 mL InDEx detector. The detector was operated at an ambient temperature of 28°C, corresponding to the (Seitz) recoil energy threshold of 4.26 keV. Measurements were performed with and without neutron shielding. A 20 cm paraffin shield was used to suppress the background neutron contribution, resulting in an approximately 85% reduction in the observed background rate. Using the paraffin-shielded data, preliminary constraints on the spin-independent DM nucleon cross section were obtained for conventional Galactic halo DM. At the 4.26 keV energy threshold, the analysis shows that the present InDEx detector can probe Galactic halo DM down to a minimum mass of approximately 3.58 GeV/$c^2$ for carbon and 4.22 GeV/$c^2$ for fluorine. To explore the possibility of extending the sensitivity to lower masses, the CRDM framework was studied for the above measurement. The calculation includes cosmic-ray spectra, scattering kinematics, nuclear form factors, and the attenuation of boosted dark matter while passing through the Earth's atmosphere and crust. The numerical framework was validated by reproducing established XENON1T results. The CRDM analysis demonstrates that the additional energy acquired through cosmic-ray scattering enables InDEx to probe DM in the order of MeV-keV mass ranges. This study demonstrates the potential of InDEx to extend dark matter searches to lower masses through the CRDM scenario, beyond the mass range accessible to conventional Galactic halo dark matter at the present detector energy threshold.

Tracks Astroparticle Physics & Cosmology

Author

Ms Mili Mandal (Saha Institute of Nuclear Physics, Homi Bhaba National Institute)

Co-authors

Prof. Mala Das (Saha Institute of Nuclear Physics, Homi Bhaba National Institute) Dr Utkarsh Patel (Saha Institute of Nuclear Physics) Prof. Anirban Das (Saha Institute of Nuclear Physics, Homi Bhaba National Institute) Mr Nilanjan Biswas (Saha Institute of Nuclear Physics) Prof. Ranjan Laha (Indian Institute of Science)

Presentation materials

There are no materials yet.