A setup for precise reconstruction of muon tracks

Not scheduled
20m
CCE (IIT Hyderabad)

CCE

IIT Hyderabad

https://physics.iith.ac.in/daehep2026/
Poster

Speaker

Shvetaank Tripathi (Bhabha Atomic Research Center; Homi Bhabha National Institute)

Description

Muons are charged particles, which are produced in cosmic shower events, as a decay product of pions or kaons in the atmosphere. These particles also tend to decay but due to their relativistic speeds, most of them reaches the surface of Earth. These are minimum ionizing particles, and thus they lose a part of their energy as they interact with the detector material. In this work, we detect the muons coming at higher zenith angles (> 60$^{\circ}$) using a setup of eight plastic scintillator bars, each of which are hanged vertically, parallel to each other. We have also devised a method to distinguish muon events from random hits and background cosmic showers, since the muon flux at higher angles is very low.

In our experimental setup, all the eight plastic bars are connected with Photomultipliers at both ends to determine the precise location of a hit. The analog signal from each hit is sent to the digitizer and we use CoMPASS software to save the data as a root file. Later, we do the offline analysis of the data to determine the muon events.

We are using coincidence technique from the six middle bars. Then on each event we apply two global cuts : Energy cut of minimum 1.44 MeV and total time duration to be within 8 ns. We have also defined several track quality parameters to further reject the background :

  1. $\chi^2/\text{NDF}$ : Calculated by fitting the points where we have measured the signal in each detector with a straight line. This must be less than 10.0
  2. $\chi^2/\text{NDF(time)}$ : This parameter is derived from a straight-line fit to the cumulative time-of-flight versus relative distance profile across six tracking detectors. This must be less than 5.0
  3. Track Velocity : This parameter is the slope of fitted straight line in time vs distance plot. The velocity must be between 20-50 cm/ns.
  4. $E_{rms}$ : It denotes the root mean square value of deviation of measured energy depositions in each detectors with the mean value. \begin{equation}
    E_{rms} = \sqrt{\frac{1}{6}\sum_{i=0}^{5}\Big(\frac{E_i - \bar{E}}{E_i}\Big)^2},
    \end{equation}
    where $E_i$ denotes the energy deposited in each detector and $\bar{E}$ denotes the mean value of all $E_i$s. The upper limit of this value is 0.6

During initial runs, we have have detected 3317 events from all hits within 8 ns, out of which 3292 satisfy all the cuts. These events are reported as muons. The rest of 25 events which were recorded within 8 ns duration can not be rejected as the possibility of such an event other than being a muon is cosmic shower. The shower constitutes $\sim$ 0.75% of total events.

Tracks Astroparticle Physics & Cosmology

Author

Shvetaank Tripathi (Bhabha Atomic Research Center; Homi Bhabha National Institute)

Co-author

Dr Prashant Shukla (Bhabha Atomic Research Center; Homi Bhabha National Institute)