Speaker
Description
The presentation compares Towerjazz 180 nm technology, used in current sensors at CERN, with TPSCo 65 nm technology for future molythic pixel detectors. The new technology will then be presented in relation to the target parameters of the OCTOPUS project, using measurement results from the already constructed MOSAIX prototype. The presentation will then cover the current status of the OCTOPUS project and the proposed detector. The design of the analog circuit, specifically, the parameters of the pixel array and the bias and monitoring circuits, will be discussed in detail. The implementation of the digital circuit processesing data from the pixel array will be briefly introduced, and the presentation will conclude with an overview of the current and future design of the OCTOPUS project detector.